 After 2 Lamp Series Ballast is Replaced

2 Lamp Series Ballast

Factory Wiring

How to Replace 2 Lamp Series Ballast with Parallel

A 2 lamp series magnetic ballast should be replaced with a 2 lamp parallel electronic ballast. Each lampholder has four separate connections.

  1. Connect each of the individual blue wires from the parallel ballast to each pair of the lampholder individual wires (red and blue).
  2. Connect the common red wire from the parallel ballast to the yellow pair of lampholder common wires.